Stabilità Proteica

at1122-bis

Titrators

TITRALAB AT1000 HACH LANGE:
Reliable results and easy setup.

degaser

Preparation

Highly effective systems to quickly remove CO2 on food samples such as wine, must, beer and beverages in general.

arredo-laboratorio

Technical furnishings

Exacta Labcenter spa offers a wide range of technical furniture.

solfotechs

Solfotech S

Automatic instrument for the determination of sulfur dioxide in musts, wines and its derivatives.

italol

Italo

ITALO series Automatic Enzymatic Analyzer with touchscreen Pc.

ph

PH

Bench and portable PH-meters. Easy to use, quick responses for desired applications.

Turbidimeter

PORTABLE TURBIDIMETER 2100 Q ISO compliant with ISO 7027
Optical system equipped with 2 detector ratios that allows obtaining accurate results in routine analyses performed according to
the EN-DIN-ISO 7027 standard.
Technical data:
Measurement principle: Nephelometry
Measurement method: 90° refracted light analysis
Operating modes: Manual or automatic range selection
Measurement range: NTU
Measurement ranges: 0-1000 NTU in automatic range selection mode; 0-9.99, 0-99.9 and 0-1000 NTU
in manual range selection mode
Accuracy: ±2% of reading value; ±1 on the last significant digit in the range 0-500 NTU;
±3% of reading value between 500-1000 NTU
Resolution: 0.01 on the lowest range
Reproducibility: ±1% of reading value or ±0.01 NTU
Light source: 870 nm IR LED
LCD display.
Accessories included:
6 cuvettes, 4 StabCal formazin primary standards of 100 ml each (<0.1, 20, 100 and 800 NTU),
Set of Gelex secondary standards, Silicone oil, Cleaning cloth for cuvettes, Instruction manual, Carrying case.

Standard Turbidity

Highly accurate turbidity standards composed of suspended microspheres, suitable for instrument calibration and control of all turbidimeters. Stable, shelf life 2 years (from date of manufacture). NIST traceable, US EPA approved and tested in accordance with ISO 7027.
100 ml HDPE bottles.

Two ranges available:
Range Ratio for Ratio Turbidity Measurement instruments (measurement of the light scattered by the sample at a 90° angle to the incident light, plus additional angles – different detectors).
Non Ratio for Non Ratio Turbidity measurement instruments, which will measure the light scattered by the sample at a 90° angle to the incident light (one detector).

Memmert bain-marie

Benchtop water bath made of high-quality, corrosion-resistant and easy-to-clean stainless steel for the working chamber and housing.
Temperature range: + 5 °C above ambient up to 95 °C; Accuracy: 0.1 °C
Volume: 10 liters
Interior:
Perfect for everyday laboratory use: The high-quality stainless steel tank with rounded corners is easy to clean and can be completely emptied using the standard drain valve without leaving any residue.
Compact and ergonomic design: The Memmert WTB fits on any laboratory bench.
Controller: Intuitive 3.5″ color graphic display with touch screen.
Timer: Digital from 1 min. to 99 hours 59 min., visual and acoustic.
Controller: Digital display of set and actual temperature and program (remaining) time.
Control:
– Temperature control: two-stage safety system to prevent overtemperature; individually adjustable, visual and acoustic overtemperature alarm; independent temperature limiter to switch off the heating in the event of a fault.
– Self-diagnostic system: microprocessor PID temperature controller with integrated self-diagnostic system with fault indicator.